排污泵,帶切割裝置排污泵,潛水排污泵
型號(hào) | 流量 | 揚(yáng)程 | 出水配管口徑 | 功率 | 轉(zhuǎn)速 |
WQK8-12QG | 8 | 12 | 32 | 0.75 | 2900 |
WQK20-7QG | 20 | 7 | 50 | 0.75 | 1450 |
WQK10-12QG | 10 | 12 | 40 | 1.1 | 1450 |
WQK8-22QG | 8 | 22 | 25 | 1.1 | 1450 |
WQK20-15QG | 20 | 15 | 50 | 1.5 | 1450 |
WQK15-30QG | 15 | 30 | 40 | 2.2 | 1450 |
WQK20-20QG | 20 | 20 | 50 | 2.2 | 1450 |
WQK25-15QG | 25 | 15 | 65 | 2.2 | 1450 |
WQK40-7QG | 40 | 7 | 80 | 2.2 | 1450 |
WQK30-15QG | 30 | 15 | 80 | 3 | 2900 |
WQK25-30QG | 25 | 30 | 65 | 4 | 2900 |
WQK40-15QG | 40 | 15 | 80 | 4 | 1450 |
WQK85-10QG | 82 | 10 | 100 | 4 | 1450 |
WQK65-25QG | 65 | 25 | 80 | 7.5 | 2900 |
WQK80-20QG | 80 | 20 | 80 | 7.5 | 1450 |
WQK100-15QG | 100 | 15 | 100 | 7.5 | 1450 |
WQK100-25QG | 100 | 25 | 100 | 11 | 1450 |
WQK115-15QG | 115 | 15 | 125 | 15 | 1450 |
WQK180-15QG | 180 | 15 | 150 | 15 | 1450 |
四、使用注意事項(xiàng)
(1)電泵使用之前,須首先檢查電纜有否損壞,搬運(yùn)和安裝水泵時(shí)切鐵拉扯或損傷電纜以免電纜破裂后漏水造成事故。如電纜硬裂后應(yīng)立即更換電纜。并用兆歐表檢查電泵的絕緣電阻是否正常(絕緣電阻不得小于1兆歐)
(2)認(rèn)清接地線(地線一般為黃、綠雙色或接有接地標(biāo)志),按規(guī)定程序接妥地線。(本廠接地線配有接地標(biāo)志)。
(3)選用合適的保護(hù)器(如漏電保護(hù)器,空氣開(kāi)關(guān),斷相過(guò)流保護(hù)器等)切勿用閘刀開(kāi)關(guān)直接連接。
(4)按標(biāo)準(zhǔn)接好電源線,試接電源,檢查電泵運(yùn)轉(zhuǎn)是否正常,并判斷轉(zhuǎn)向是否正確,若轉(zhuǎn)向不正確,將三根電源線中的任意二根對(duì)換接好即可(注意運(yùn)轉(zhuǎn)時(shí)間不能超過(guò)半分鐘)。
(5)裝好出水接頭及出水膠管(或鐵管),在電泵提手上結(jié)好繩索(不能用電纜代替吊繩的作用),將電泵放入被抽液本中,接通電源,即可使用。