| | | | * Electro-mechanical scale conversions * Hopper and tank weighing * Conveyor Scale * Tensile testing, force measuring applications * Crane Scales (only with proper safety device for unexpectedbreakage of the load cells) | * Rationalized output * Bi-direction(tension/compression) * Electroless nickel plated high alloy tool steel or stainlesssteel construction * NTEP Class III 5,000S available from 250 lb to 20k lb for STC ofalloy steel * NTEP Class III 5,000S available from 25 lb to 25k lb for STR ofalloy steel | | | | * S Type load cell as the nameindicated can be easily identified by its S-shaped body. They canbe loaded either in tension or compression, and used for single ormultiple-cell application if the output is rationalized. * STC is made of alloy or stainless steel and is NTEP approved. * STC Interchangeable products: - Rice Lake Weighing Systems RL20001 HE
- Sensortronics 60063
| | | Standard Capacity | 200, 250, 300, 500, 750, 1K,1.5K, 2K, 2.5K, 3K, 5K, 7.5K, 10K, 15K, 20K, 40K lb 25, 50, 75, 100, 250, 500, 750, 1000, 1500, 2000, 2500,5000kg | Recommended Excitation | 10 V AC/DC | Compensated Temp. Range | -10°C to +40°C | Maximum Excitation | 15 V AC/DC | Operating Temp. Range | -20°C to +60°C | Output at Rated Load | 3 mV/V±10% | Zero Balance | ±1% | Combined Error | 0.02% (SS:0.03%) | Input Resistance | 385±5 Ω | Non Repeatability | 0.01% | Output Resistance | 350±3Ω | Creep (20 minutes) | 0.03% | Insulation Resistance(50VDC) | >5000 MΩ | Zero Return (20 minutes) | 0.03% | Deflection at Rated Load | <1mm | Temp. Effect/10°C on Span | 0.015% | Safe Overload | 150% | Temp. Effect/10°C on Zero | 0.026% | Ultimate Overload | 300% |
| All Specifications Listed Subject To ChangeWithout Notice |
|