Product Features
- Reliable and repeatable measurements
- Simple to maintain, easy to calibrate
- Robust design
- Quick and easy to install
- Simple to use
Technical Specification
Sensor Type XZR-500-ST + XCU-500-WM Measurement Principle Zirconium Oxide Sensor with Metallic Sealed Reference and K Type T/C Performance Gas Wet, dirty and hot Measurement Range 0.01-25% Oxygen Accuracy <2% relative with atmospheric pressure compensation Response Time < 15s for 90% of response step from calibration gas inlet Repeatability ±0.1% Fidelity 1% per month Linearity Better than ±1% Sample Flow Rate Flue Gas at 0.5 m/s minimum rate Maximum Sample Pressure Depending on application Maximum Sample Temperature Up to 1300°C on request Outputs Output Signal One off 0/4 to 20 mA linear with Galvanic Insulation Output; 2nd optional output Output Load Over 1000 Ω Self-diagnostics Included in Readout Output Ranges Freely configurated between 0.01-25% Alarms 2 Alarms; User adjustable (10 W)
1 Fault AlarmDisplay Resolution 0.1% in standard; (0.01% on request) Power Supply 115 or 220 VAC, 50/60 Hz Power Consumption 110 VA Ambient Temperature Range 0°C to 55°C Sensor Temperature 600 to 800°C, optimised at 700°C Operating Humidity 5-90% RH without condensation Physical Dimensions 300 x 300 x 200 mm (Control)
290 x 135 x 650 mm (Sensor)Weight 10 to 15kg depending on application Wetted Materials XZR-501- 304 L Stainless steel (700°C)
XZR-502- Inconel 600 (1000°C)
XZR-503- HR160 (600°C to 1000°C)
XZR-504- C2000 (600°C)
XZR-505- Halar coating (120°C)
XZR-506- Ceramic (1300°C)Probe Dimensions Length 400mm, other on request Installation Stack and wall mounting Housing Ingress Protection Weatherproof