您好, 歡迎來(lái)到環(huán)保在線! 登錄| 免費(fèi)注冊(cè)| 產(chǎn)品展廳| 收藏商鋪|
當(dāng)前位置:齊一生物科技(上海)有限公司>>ELISA試劑盒>>小鼠ELISA試劑盒>> 小鼠白介素13(IL-13)ELISA試劑盒
參 考 價(jià) | 面議 |
產(chǎn)品型號(hào)
品 牌
廠商性質(zhì)生產(chǎn)商
所 在 地上海市
更新時(shí)間:2018-01-08 07:20:52瀏覽次數(shù):306次
聯(lián)系我時(shí),請(qǐng)告知來(lái)自 環(huán)保在線小鼠轉(zhuǎn)運(yùn)蛋白1(TNPO1) ELISA Kit
大鼠過(guò)氧化物酶體增殖物激活受體α(PPAR-α)ELISA試劑盒
小鼠白介素13(IL-13)ELISA試劑盒FOR RESEARCH USE ONLY
Drug Names
Generic Name:小鼠白介素13(IL-13)ELISA試劑盒
This kit can be used for determination of serum, plasma and liquid samples Organization Content.
The experimental principle:
The product levels were measured in samples of the kit by double antibody sandwichmethod. The product with the purified antibody coated microtiter plate, made of solid phase antibody, to package is the product antigen monoclonal antibodies are then added to the micropores, the product and then with HRP labeled antibody binding, the formation of antibody - antigen - antibody complex enzyme label, after thorough washing with TMB chromogenic substrate. TMB in the HRP enzyme catalytic conversion into the blue, and in the action of acid into the final yellow. This product is positively related to the depth of color and in the samples. Instrument measured absorbance in the 450nm wavelength with ELISA (OD), the product concentration in the samples was calculated by standard curve.
Materials provided with the kit
Materials provided with the kit 48determinations 96 determinations Storage
User manual 1 1
Closure plate membrane 2 2
Sealed bags 1 1
Microelisa stripplate 1 1 2-8℃
Standard:360ng/L 0.5ml×1 bottle 0.5ml×1 bottle 2-8℃
Standard diluent 1.5ml×1 bottle 1.5ml×1 bottle 2-8℃
HRP-Conjugate reagent 3ml×1 bottle 6ml×1 bottle 2-8℃
Sample diluent 3ml×1 bottle 6ml×1 bottle 2-8℃
Chromogen Solution A 3ml×1 bottle 6ml×1 bottle 2-8℃
Chromogen Solution B 3ml×1 bottle 6ml×1 bottle 2-8℃
Stop Solution 3ml×1 bottle 6ml×1 bottle 2-8℃
wash solution (20ml×20 fold)
×1bottle (20ml×30 fold)
×1bottle 2-8℃
小鼠白介素13(IL-13)ELISA試劑盒Specimen requirements
1.serum- coagulation at room temperature 10-20 mins,centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.
2.plasma-use suited EDTA or citrate plasma as an anticoagulant,mix 10-20 mins ,centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.
3.Urine-collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again. The Operation of Hydrothorax and cerebrospinal fluid Reference to it.
4.cell culture supernatant-detect secretory components, collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant,detect the composition of cells, Dilut cell suspension with PBS(PH7.2-7.4), Cell concentration reached 1 million / ml, repeated freeze-thaw cycles, damage cells and release of intracellular components, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.
5.Tissue samples- After cutting samples, check the weight,add PBS(PH7.2-7.4), Rapidly frozen with liquid nitrogen, maintain samples at 2-8℃ after melting,add PBS(PH7.4), Homogenized by hand or Grinders, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant.
6.extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
7.Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.
Assay procedure
1.Dilute and add sample to Standard: set 10 Standard wells on the ELISA plates coated, add Standard 100μl to the first and the second well, then add Standard dilution 50μl to the first and the second well, mix; take out 100μl form the first and the second well then add it to the third and the forth well separay. then add Standard dilution 50μl to the third and the forth well ,mix ; then take out 50μl from the third and the forth well discard, add 50μl to the fifth and the sixth well ,then add Standard dilution 50μl to the fifth and the sixth well, mix ; take out 50μl from the fifth and the sixth well and add to the seventh and the eighth well, then add Standard dilution 50μl to the seventh and the eighth well ,mix ; take out 50μl from the seventh and the eighth well and add to the ninth and the tenth well, add Standard dilution 50μl to the ninth and the tenth well, mix , take out 50μl from the ninth and the tenth well discard(add Sample 50μl to each well after Diluting ,(density: 240ng/L,160ng/L ,80ng/L,40ng/L, 20ng/L)
2.add sample:Set blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.
3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃.
4.Configurate liquid: 30-fold (or 20-fold)wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
5.washing:Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
6.add enzyme:Add HRP-Conjugate reagent 50μl to each well, except blank well.
7.incubate:Operation with 3.
8.washing:Operation with 5.
9.color:Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37℃
10.Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
11.assay:take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.
Important notes
1.The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
2.washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
3.add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 mins, if the number of sample is much , recommend to use Volley .
4.if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.(×n×5).
5.Closure plate membrane only limits the disposable use, to avoid cross-contamination.
6.The substrate evade the light preservation.
7.Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
8.All samples, washing buffer and each kind of reject should according to infective material process.
9.Do not mix reagents with those from other lots.
小鼠白介素13(IL-13)ELISA試劑盒Calculate:
Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.
Storage and validity
1.Storage: 2-8℃.
2.validity: six months.
小鼠白介素13(IL-13)ELISA試劑盒其它產(chǎn)品
292023 mericon Cattle (24)
292013 mericon Pig Kit (24)
9001903 QIAgility HEPA/UV (PC) Priority QIAgility HEPA/UV (PC) Priority includes the QIAgility instrument, installation and extended warranty. Installation covers hardware and software installation of system and provides user with introductory training. Priority package extends warranty period of the system to 2 years. One on-site pipetting head service is included for each year of the warranty; 2 pipetting head services in total. Service package includes all parts, labor and travel costs with an on site service response time of 48 hours (2 working days). Performance of the installation and service visits are documented on a GMP/GLP-compliant Field Service documents.
133122 NeXtalStock Potassium citrate (200)
963141 QIAquick 96 PCR BioRobot Kit (4) For purification of 4 x 96 PCR products: 4 QIAquick 96 Plates, Reagents, Buffers, Collection Microtubes (1.2 ml) and Caps, 96-Well Microplates RB and Lids, Tape Pads
133193 NeXtalStock di-Potassium phosphate (200)
9018555 Cover, front, top, EZ1a
9018528 User Manual EZ1 Advanced
37601 Qproteome Plasma Membrane Protein Kit
9015329 O-rings, Norpren tube fixing, M48 (2)
9015328 Seal, cap, M48 (6)
239095 GelPilot 1 kb Plus Ladder (100) Ready-to-use DNA marker, 600µl (100lanes), 12 fragments: 100 – 10000 bp
133127 NeXtalStock Sodium citrate (200)
133126 NeXtalStock TRIS-HCl pH 8.5 (200)
133008 NeXtalStock 2-Propanol (200)
133007 NeXtalStock MES sod. salt untit. (200)
9011949 Board, X-main
9011945 Tube Holder, STS, 11ml (6) Holder for accommodating 8 tubes (11 ml) in the sample tracking system; pack of 6
9243588 RCS, Premium Agreement "- Service response time RCS: 24 Hrs
- Inspection/maintenance delivery: yes, included; 1 /agreement year
- Cost coverage for repair parts: yes, included
- Cost coverage for labor: yes, included
- Cost coverage for travel: yes, included
- Replacement system provision for DML: yes, included
- Transportation cost coverage for DML: yes, included
For defect units, after customer calling QIAGEN technical service hotline before 9 am:
RCS:
- QIAGEN shall dispatch a specialist to repair the defect instrument at customer site within 24 Hrs.
DML:
- A special package containing a replacement unit shall be sent to the customer within 48 Hrs / 2 working days.
- Customer shall send the defect unit to QIAGEN Regional Repair Center following the instructions attached with the packaging.
Note: for DML owned by customer, QIAGEN Regional Repair Center will send back the repaired original unit to customers within 7-10 working days.
PC, Monitor, Heater, Shaker, Washer, Printer and Votexer:
- A new unit shall be sent to customer within 7-10 working days at no extra cost
- Customer shall send the defect unit to QIAGEN for disposal
- On-site installation of PC and application software is not covered by the agreement
The Preventive Maintenance (PM) service ensures the correct operation of the equipment. During the PM, all the instrument modules are inspected by a qualified QIAGEN service technician. The Preventive Maintenance is performed under the manufacturer guidelines and documented according to GLP / GMP"
37013 Albumin Affinity Cartridges (3 x 1ml)
36910 Single-Tube Magnet Magnet for separating magnetic particles in a 1.5 ml or 2 ml tube
36111 Ni-NTA Magnetic Agarose Beads (2 x 1 ml) 2 x 1 ml nickel-charged magnetic agarose beads (5% suspension)
35330 Penta-His Alexa Fluor 532 Conjugate 125 ul Penta-His Alexa Fluor 532 Conjugate, 200 ug/ml
218432 Mouse miScript Assay 384 Set VXX.X (20)
218412 Mouse miScript Primer Assay Set VXX.X
218380 #miScript PCR Control Set miScript PCR Control Set allows customers to identify easily the right normalization control for their real-time PCR set up while working with miRNAs or other small RNAs. It includes 6 normalization control assays (for 50 real-time PCR rxns a 50µl) which are all designed against snoRNAs or snRNAs. Works for human mouse and rat.
218193 miScript PCR Starter Kit (80)
9018294 EZ1 Advanced DNA Buffy Coat Card
800356 Handling Fee
9015298 Nozzles, M48 (6)
9243775 QIAsymphony AS Custom Protocol Advanced2
9019447 Sensor brd 4 CH temp sensor
9019444 Electrolytic capacitor 8000uF x 63V
9018158 Waste station, waste drawer, Qsym
9018154 Bottle, waste drawer, Qsym
9018135 Sensor, xz, et/hs, Qsym
9018132 Splash guard, extractor, Qsym
9017720 Appl. Pack Investigator for Univ.PF
9017832 Sensor, tip check, QIAC
9017830 Power entry port, QIAC
9017828 Power supply, 230 V, QIAC
9017821 Board, main, QIAC
9017820 Flexcircuit, display, 40 pol. , QIAC
9017812 Board, centrifuge (240V), QIAC
4846024 careUU PCR ASSAY
4861024 careEBV PCR ASSAY II
130906 NeXtal DWBlock MPD Suite
4518265 artus HCV RG RT-PCR Kit (96) CE
130720 NeXtal Tubes JCSG+ Suite
129114 Nuclease-Free Water (10 x 50 ml)
4504065 artus Parvo B19 LC PCR Kit (96) CE
120025 TurboFilter 96 Plates (96) 96 TurboFilter 96 Plates
4505065 artus HAV LC RT-PCR Kit (96) CE
4506063 artus HBV LC PCR Kit (24) CE
75742 RNeasy Fibrous Tissue Midi Kit (10) 10 RNeasy Midi Spin Columns, Collection Tubes (15 ml), Proteinase K, RNase-free DNase I, RNase-free Reagents and Buffers
74181 RNeasy 96 Kit (4) For 4 x 96 total RNA preps: 4 RNeasy 96 Plates, Elution Microtubes CL (1.2 ml), Caps, RNase-free Reagents and Buffers
28053 MinElute 96 UF PCR Purification Kit (24) 24 MinElute 96 UF PCR Purification Plates
74121 RNeasy Protect Starter Kit RNAlater RNA Stabilization Reagent (20 ml), 6 RNeasy Mini Spin Columns, 2 RNeasy Midi Spin Columns, Collection Tubes (1.5 and 2 ml), RNase-free Reagents and Buffers
74104 RNeasy Mini Kit (50) 50 RNeasy Mini Spin Columns, Collection Tubes (1.5 ml and 2 ml), RNase-free Reagents and Buffers
72251 TurboCapture 96 mRNA Kit (5) For rapid and easy mRNA purification in high-throughput applications. The kit provides a fast and simple procedure for purifying mRNA. Up to 96 samples can be processed simultaneously - ideal for high-throughput applications such as compound screening and target validation (e.g. by siRNA screening).
19407 VacConnectors (500) 500 disposable connectors for use with QIAamp spin columns on luer connectors. Should be ordered in conjuntion with 19408 - VacValves (24).
12281 QIAfilter Plasmid Mega Kit (5) 5 QIAGEN-tip 2500, Reagents, Buffers, 5 QIAfilter Mega-Giga Cartridges
12191 QIAGEN Plasmid Giga Kit (5) 5 QIAGEN-tip 10000, Reagents, Buffers
4502103 artus VZV TM PCR Kit (24) RUO
133271 NeXtalStock PIPES pH 7.0 (200)
133270 NeXtalStock Phosphate-citr. pH 5.2 (200)
990512 Filter-Tips, 50 µl (960)
337620 qBiomarker SYBR Green Fluor Mastermix(2)
337011 qBiomarker Somatic Mutations PCR Assays
4500263 artus HSV-1/2 RG PCR Kit (24) CE
939016 Buffer ATL ( 4 x 50 ml),GPR
4500163 artus HSV-1/2 TM PCR Kit (24) CE
請(qǐng)輸入賬號(hào)
請(qǐng)輸入密碼
請(qǐng)輸驗(yàn)證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),環(huán)保在線對(duì)此不承擔(dān)任何保證責(zé)任。
溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。