大鼠髓磷脂堿性蛋白(MBP)ELISA試劑盒使用說明

1
Rat myelin basic protein (MBP) ELISA Kit
Catalog Number. CSB-E08284r
For  the quantitative  determination of  rat myelin basic protein (MBP)
concentrations in serum, plasma, tissue homogenates.
This package insert must be read in its entirety before using this product.

In order to obtain higher efficiency service, please ready to supply the lot number 
of the kit to us (found on the outside of the box).2
PRINCIPLE OF THE ASSAY
This assay employs the quantitative sandwich enzyme immunoassay technique. 
Antibody specific for MBP has been pre-coated onto a microplate. Standards 
and samples are pipetted into the wells and any MBP present is bound by the 
immobilized antibody. After  removing  any unbound substances, a 
biotin-conjugated antibody specific for MBP is added to the wells. After washing,
avidin conjugated Horseradish Peroxidase (HRP) is added to the wells.
Following a wash to remove any unbound avidin-enzyme reagent, a substrate 
solution is added to the wells and color develops in proportion to the amount of 
MBP bound in the initial step. The color development is stopped and the intensity 
of the color is measured.
DETECTION RANGE
0.312 ng/ml-20 ng/ml.
SENSITIVITY
The minimum detectable dose of rat MBP is typically less than 0.078 ng/ml.
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as 
the lowest protein concentration that could be differentiated from zero. It was 
determined the mean O.D value of 20 replicates of the zero standard added by 
their three standard deviations.
SPECIFICITY
This assay has high sensitivity and excellent specificity for detection of rat MBP. 
No significant cross-reactivity or interference  between rat MBP and analogues 
was observed.
Note: Limited by current skills and knowledge, it is impossible for us to complete 
the cross-reactivity detection between rat MBP and all the analogues, therefore,
cross reaction may still exist.3
PRECISION
Intra-assay Precision (Precision within an assay): CV%<8%
Three samples of known concentration were tested twenty times on one plate to 
assess.
Inter-assay Precision (Precision between assays): CV%<10%
Three samples of known concentration were tested in twenty assays to assess.
LIMITATIONS OF THE PROCEDURE
? FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC 
PROCEDURES.
? The kit should not be used beyond the expiration date on the kit label.
? Do not mix or substitute reagents with those from other lots or sources.
? If samples generate values higher than the highest standard, dilute the 
samples with Sample Diluent and repeat the assay.
? Any variation in  Sample Diluent, operator, pipetting technique, washing 
technique, incubation time or temperature, and kit age can cause variation 
in binding.
? This assay is designed to eliminate interference by soluble receptors, 
binding proteins, and other factors present in biological samples. Until all 
factors have been tested in the Immunoassay, the possibility of 
interference cannot be excluded.4
MATERIALS PROVIDED
Reagents Quantity
Assay plate (12 x 8 coated Microwells) 1(96 wells)
Standard (Freeze dried) 2
Biotin-antibody (100 x concentrate)  1 x 120 μl
HRP-avidin (100 x concentrate) 1 x 120 μl
Biotin-antibody Diluent   1 x 15 ml
HRP-avidin Diluent    1 x 15 ml
Sample Diluent   1 x 50 ml
Wash Buffer (25 x concentrate) 1 x 20 ml
TMB Substrate  1 x 10 ml
Stop Solution   1 x 10 ml
Adhesive Strip (For 96 wells) 4
Instruction manual 1
STORAGE
Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date
Opened kit
Coated assay 
plate
May be stored for up to 1 month at 2 - 8°C. 
Try to keep it in a sealed aluminum foil bag,
and avoid the damp.
Standard May be stored for up to 1 month at 2 - 8° C. If 
don’t make recent use, better keep it store at 
-20°C.
Biotin-antibody 
HRP-avidin
Biotin-antibody 
Diluent
May be stored for up to 1 month at 2 - 8°C.
HRP-avidin 
Diluent
Sample 
Diluent
Wash Buffer
TMB 
Substrate
Stop Solution
*Provided this is within the expiration date of the kit.5
OTHER SUPPLIES REQUIRED
? Microplate reader capable of measuring absorbance at 450 nm, with the 
correction wavelength set at 540 nm or 570 nm.
? An incubator which can provide stable incubation conditions up to 
37°C±0.5°C.
? Squirt bottle, manifold dispenser, or automated microplate washer.
? Absorbent paper for blotting the microtiter plate.
? 100 ml and 500 ml graduated cylinders.
? Deionized or distilled water.
? Pipettes and pipette tips.
? Test tubes for dilution.
PRECAUTIONS
The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, 
and clothing protection when using this material.6
SAMPLE COLLECTION AND STORAGE
? Serum   Use a serum separator tube (SST) and allow samples to clot for 
two hours at room temperature or overnight at 4°C before centrifugation 
for 15 minutes at 1000 ×g. Remove serum and assay immediay or 
aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw 
cycles.
? Plasma   Collect plasma using EDTA, or heparin as an anticoagulant. 
Centrifuge for 15 minutes at 1000 x g, 2  - 8°C within 30 minutes of 
collection. Assay immediay or aliquot and store samples at  -20°C or 
-80°C. Avoid repeated freeze-thaw cycles. Centrifuge the sample again 
after thawing before the assay.
? Tissue Homogenates   100mg tissue was rinsed with 1X PBS, 
homogenized in 1 ml of 1X PBS and stored overnight at -20°C. After two 
freeze-thaw cycles were performed to break the  cell membranes, the 
homogenates were centrifuged for 5 minutes at 5000 x g, 2 - 8°C. The 
supernate was removed and assayed immediay. Alternatively, aliquot 
and store samples at -20°C or -80°C. Centrifuge the sample again after 
thawing before the assay. Avoid repeated freeze-thaw cycles.7
Note:
1. CUSABIO is only responsible for the kit itself, but not for the samples 
consumed during the assay. The user should calculate the possible 
amount of the samples used in the whole test. Please reserve sufficient
samples in advance.
2. Samples to be used within 5 days may be stored at 2-8°C, otherwise 
samples must be stored at -20°C (≤1month) or -80°C (≤2month) to avoid 
loss of bioactivity and contamination.
3. Grossly hemolyzed samples are not suitable for use in this assay.
4. If the samples are not indicated in the manual, a preliminary experiment to 
determine the validity of the kit is necessary. 
5. Please predict the concentration before assaying. If values for these are 
not within the range of the standard curve, users  must determine the 
optimal sample dilutions for their particular experiments.
6. Tissue or cell extraction samples prepared by chemical lysis buffer may 
cause unexpected ELISA results due to the impacts of certain chemicals.
7. Owing to the possibility of mismatching between antigen from other 
resource and antibody used in our kits (e.g., antibody targets 
conformational epitope rather than linear epitope), some native or 
recombinant proteins from other manufacturers may not be recognized by 
our products.
8. Influenced by the factors including cell viability, cell number and also 
sampling time, samples from cell culture supernatant may not be detected 
by the kit.
9. Fresh samples without long time storage are recommended for the test. 
Otherwise, protein degradation and denaturalization may occur in those 
samples and finally lead to wrong results.8
REAGENT PREPARATION
Note: 
? Kindly use graduated containers to prepare the reagent. Please don't 
prepare the reagent directly in the Diluent vials provided in the kit.
? Bring all reagents to room temperature (18-25°C) before use for 30min.
? Prepare fresh standard for each assay. Use within 4 hours and discard 
after use.
? Making serial dilution in the wells directly is not permitted. 
? Please carefully reconstitute Standards according to the instruction, and 
avoid foaming and mix gently until the crystals have compley dissolved. 
To minimize imprecision caused by pipetting, use small volumes and 
ensure that pipettors are calibrated. It is recommended to suck more than 
10μl for once pipetting.
? Distilled water is recommended to be used to make the preparation for 
reagents or samples. Contaminated water or container for reagent 
preparation will influence the detection result.
1. Biotin-antibody (1x) - Centrifuge the vial before opening. 
Biotin-antibody requires a 100-fold dilution. A suggested 100-fold dilution 
is 10 μl of Biotin-antibody + 990 μl of Biotin-antibody Diluent.
2. HRP-avidin (1x) - Centrifuge the vial before opening.
HRP-avidin requires a 100-fold dilution. A suggested 100-fold dilution is 10 
μl of HRP-avidin + 990 μl of HRP-avidin Diluent.
3. Wash Buffer(1x)- If crystals have formed in the concentrate, warm up to    
room temperature and mix gently until the crystals have compley 
dissolved. Dilute 20 ml of Wash Buffer Concentrate (25 x) into deionized or 
distilled water to prepare 500 ml of Wash Buffer (1 x).9
4. Standard 
Centrifuge the standard vial at 6000-10000rpm for 30s. 
Reconstitute the  Standard with 1.0 ml of  Sample Diluent. Do not 
substitute other diluents. This reconstitution produces a stock solution of 
20 ng/ml. Mix the standard to ensure complete reconstitution and allow the 
standard to sit for a minimum of 15 minutes with gentle agitation prior to 
making dilutions. 
Pipette 250 μl of Sample Diluent into each tube (S0-S6). Use the stock 
solution to produce a 2-fold dilution series (below). Mix each tube 
thoroughly before the next transfer. The undiluted Standard serves as the 
high standard (20 ng/ml). Sample Diluent serves as the zero standard (0 
ng/ml).
Tube S7 S6 S5 S4 S3 S2 S1 S0
ng/ml 20 10 5 2.5 1.25 0.625 0.312 010
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. Centrifuge 
the sample again after thawing before the assay. It is recommended that all 
samples and standards be assayed in duplicate. 
1. Prepare all reagents, working standards, and samples as directed in the 
previous sections.
2. Refer to the Assay Layout Sheet to determine the number of wells to be 
used and put any remaining wells and the desiccant back into the pouch 
and seal the ziploc, store unused wells at 4°C.
3. Add 100μl of standard and sample per well. Cover with the adhesive strip
provided. Incubate for 2 hours at 37°C. A plate layout is provided to record 
standards and samples assayed.
4. Remove the liquid of each well, don’t wash. 
5. Add 100μl of  Biotin-antibody (1x)  to each well. Cover with a new 
adhesive strip. Incubate for 1 hour at 37°C.  (Biotin-antibody (1x) may 
appear cloudy. Warm up to room temperature and mix gently until solution 
appears uniform.)
6. Aspirate each well and wash, repeating the process two times for a total of 
three washes. Wash by filling each well with Wash Buffer (200μl) using a 
squirt bottle, multi-channel pipette, manifold dispenser, or autowasher,
and let it stand for 2 minutes, complete removal of liquid at each step is 
essential to good performance. After the last wash, remove any remaining 
wash Buffer by aspirating ordecanting. Invert the plate and blot it against 
clean paper towels.
7. Add 100μl of HRP-avidin (1x) to each well. Cover the microtiter plate with 
a new adhesive strip. Incubate for 1 hour at 37°C.
8. Repeat the aspiration/wash process for five times as in step 6.
9. Add 90μl of TMB Substrate to each well. Incubate for 15-30 minutes at 
37°C. Protect from light.
10. Add 50μl of Stop Solution to each well,  gently tap the plate to ensure 
thorough mixing.11
11. Determine the optical density of each well within  5 minutes, using a 
microplate reader set to 450 nm. If wavelength correction is available, set 
to 540 nm or 570 nm. Subtract readings at 540 nm or 570 nm from the 
readings at 450 nm. This subtraction will correct for optical imperfections 
in the plate. Readings made directly at 450 nm without correction may be 
higher and less accurate.
*Samples may require dilution. Please refer to Sample Preparation section.
Note:
1. The final experimental results will be closely related to validity of the 
products, operation skills of the end users and the experimental 
environments. 
2. Samples or reagents addition: Please use the freshly prepared Standard. 
Please carefully add samples to wells and mix gently to avoid foaming. Do 
not touch the well wall as possible. For each step in the procedure, total 
dispensing time for addition of reagents or samples to the assay plate 
should not exceed 10 minutes. This will ensure equal elapsed time  for 
each pipetting step, without interruption. Duplication of all standards and 
specimens, although not required, is recommended. To avoid 
cross-contamination, change pipette tips between additions of each 
standard level, between sample additions, and between reagent additions. 
Also, use separate reservoirs for each reagent.
3. Incubation: To ensure accurate results, proper adhesion of plate sealers 
during incubation steps is necessary. Do not allow wells to sit uncovered 
for extended periods between incubation steps. Once reagents have been 
added to the well strips, DO NOT let the strips DRY at any time during the 
assay. Incubation time and temperature must be observed.
4. Washing: The wash procedure is critical. Complete removal of liquid at 
each step is essential to good performance. After the last wash, remove 
any remaining Wash Solution by aspirating or decanting and remove any 
drop of water and fingerprint on the bottom of the plate. Insufficient 
washing will result in poor precision and falsely elevated absorbance 
reading. When using an automated plate washer, adding a 30 second 
soak period following the addition of wash buffer, and/or rotating the plate 
180 degrees between wash steps may improve assay precision.12
5. Controlling of reaction time: Observe the change of color after adding TMB 
Substrate (e.g. observation once every 10 minutes), TMB Substrate
should change from colorless or light blue to gradations of blue. If the color 
is too deep, add Stop Solution in advance to avoid excessively strong 
reaction which will result in inaccurate absorbance reading.
6. TMB Substrate is easily contaminated.  TMB Substrate should remain 
colorless or light blue until added to the plate. Please protect it from light.
7. Stop Solution should be added to the plate in the same order as the TMB 
Substrate. The color developed in the wells will turn from blue to yellow 
upon addition of the Stop Solution. Wells that are green in color indicate 
that the Stop Solution has not mixed thoroughly with the TMB Substrate.13
ASSAY PROCEDURE SUMMARY
*Samples may require dilution. Please refer to Sample Preparation section.14
CALCULATION OF RESULTS
Using the professional soft "Curve Expert 1.3" to make a standard curve is 
recommended, which can be downloaded from our web.
Average the duplicate readings for each standard and sample and subtract the 
average zero standard optical density. 
Create a standard curve by reducing the data using computer software capable 
of generating a four parameter logistic (4-PL) curve-fit. As an alternative, 
construct a standard curve by plotting the mean absorbance for each standard 
on the x-axis against the concentration on the y-axis and draw a best fit curve 
through the points on the graph. The data may be linearized by plotting the log of 
the MBP concentrations versus the log of the O.D. and the best fit line can be 
determined by regression analysis. This procedure will produce an adequate but 
less precise fit of the data. 
If samples have been diluted, the concentration read from the standard curve
must be multiplied by the dilution factor.

慧嘉生物您實驗身邊的好伙伴

為客戶提供“zui高品質(zhì)的產(chǎn)品”和“zui的服務(wù)”

詳細說明書及技術(shù)咨詢 

 陳

:1193953234      1048735792


環(huán)保在線 設(shè)計制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://szhxt8.com.cn,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責,環(huán)保在線對此不承擔任何保證責任。 溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~
奇米精品一区二区三区在线观看| 丝瓜视频黄色| 色色免费视频网站| jiuse九色最新地址| 草草网站| 秋霞视频在线| 69熟女| 综合网激情| 999AV视频| 国产精品-区区久久久狼| 国产亚洲精品无码成人妖精影视 | 人妻丰满熟妇aV无码| 久久久综合激的五月天| 日韩欧美三级片网站| 天堂av成人无码久久免费精品 | 亚洲精品国产综合99久久夜夜嗨| 性欧美暴力猛交69hd| 久久精品无码一区二区av黄鳝| xxxwww日本| 熟妇人妻无乱码中文字幕蜜桃| 久久精品国产亚洲AV麻豆色欲| 亚洲无码日韩中文字幕| 久久福利精品| 一木久道热线| 欧美激情91| 91精品国产日韩91久久久久久| 国产乱子影视频上线免费观看 | 日本乱子人伦在线视频| 男女视频网址| 亚洲无码精品视频在线观看| 国产精品欧美久久久久三级| 人妻丰满熟妇av无码区本子| 国产精品,亚洲无码| 69久久99精品久久久久婷婷| 变态另类在线观看| 精品1区| wwwwww色| 免费无码专区毛片高潮喷| 北岛玲久久一区二区三区电影| 91香蕉视频污污| 在线国产h|