0.999"]]],["p",{"rPr":{"fonts":{"hint":"default"},"sz":12,"szUnit":"pt"}},["span",{"data-type":"text"},["span",{"fonts":{"hint":"default"},"sz":12,"szUnit":"pt","data-type":"leaf"},"10) 主 機 規(guī) 格:450mm(長) x 300mm(寬) x 200mm(高) 12kg"]]],["p",{"rPr":{"fonts":{"hint":"default"},"sz":12,"szUnit":"pt"}},["span",{"data-type":"text"},["span",{"fonts":{"hint":"default"},"sz":12,"szUnit":"pt","data-type":"leaf"},"11) 電 源 功 率:220v、50Hz、50W"]]],["p",{"rPr":{"fonts":{"hint":"default"},"sz":12,"szUnit":"pt"}},["span",{"data-type":"text"},["span",{"fonts":{"hint":"default"},"sz":12,"szUnit":"pt","data-type":"leaf"},"12) 溫 濕 度:( -5~35)℃ (20~85) %"]]],["p",{"rPr":{"fonts":{"hint":"default"},"sz":12,"szUnit":"pt"}},["span",{"data-type":"text"},["span",{"data-type":"leaf"},""]]],["p",{"rPr":{"fonts":{"hint":"default"},"sz":12,"szUnit":"pt"}},["span",{"data-type":"text"},["span",{"data-type":"leaf"},""]]]]"> 1、符合標(biāo)準(zhǔn)
HJ637 -2018《水質(zhì) 石油類和動植物油的測定 紅外分光光度法》
HJ1051 -2019《土壤 石油類的測定 紅外分光光度法》
HJ1077 -2019《固定污染源廢氣 油煙和油霧的測定 紅外分光光度法》
GB 5084 -2021《農(nóng)田灌溉水質(zhì)標(biāo)準(zhǔn)》
2、應(yīng)用領(lǐng)域:
用于工業(yè)廢水、生活污水、飲食業(yè)油煙油霧、農(nóng)業(yè)環(huán)境、土壤中石油類和動植物油類的測定
3、技術(shù)指標(biāo):
1) 波 數(shù) 范 圍:3400cm-1 ~2400cm-1 (即波長范圍2941nm~4167nm)
2) 波長準(zhǔn)確度:± 1nm (即波數(shù)重復(fù)性±0.5cm-1 )
3)吸光度范圍:(0.0000~2.0000) AU,即透光率為(100~1) %T
4)檢出濃度:0.003mg/L
5)方法檢出限:0.06mg/L
6)儀器檢出限:DL≤0.06mg/L(四氯乙烯空白液測定11次的3倍SD)
7)準(zhǔn)確度誤差:≤ 1%(30mg/L~50mg/L)
8)重復(fù)穩(wěn)定性:RSD≤0.6%(30mg/L~50mg/L)
9) 線 性 系 數(shù):r>0.999
10) 主 機 規(guī) 格:450mm(長) x 300mm(寬) x 200mm(高) 12kg
11) 電 源 功 率:220v、50Hz、50W
12) 溫 濕 度:( -5~35)℃ (20~85) %