型號 | HS-500-12 | HS-500-15 | HS-500-24 | HS-500-36 | HS-500-48 | |
輸出 | 直流電壓 | 12V | 15V | 24V | 36V | 48V |
額定電流 | 41.6A | 33.3A | 20.83A | 13.8A | 10.41A | |
電流范圍 | 0~41.6A | 0~33.3A | 0~20.83A | 0~13.8A | 0~10.41A | |
額定功率 | 500W | 500W | 500W | 500W | 500W | |
紋波與噪聲 | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
電壓調(diào)整范圍 | 10.2~13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V | |
電壓精度 | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
線性調(diào)整率 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
負(fù)載調(diào)整率 | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
啟動,上升時間 | 1300ms,50ms/230VAC 1300ms,50ms/115VAC (滿載時) | |||||
保持時間 | 16ms/230VAC 12ms/115VAC (滿載時) | |||||
輸入 | 電壓范圍 | 90~132VAC/180~264VAC (通過開關(guān)選擇) 240~370VDC (開關(guān)開啟230VAC) | ||||
頻率范圍 | 47~63Hz | |||||
效率 | 85% | 86% | 88% | 88.5% | 89% | |
交流電流 | 6.8A/115VAC 3.4A/230VAC | |||||
浪涌電流 | 冷啟動60A/115VAC 60A/230VAC | |||||
漏電流 | <2mA/240VAC | |||||
保護(hù) | 過負(fù)載 | 額定輸出功率的110~140% | ||||
保護(hù)模式:打嗝模式,異常條件移除后可自動恢復(fù) | ||||||
過電壓 | 13.8~16.2V | 18~21V | 28.8~33.6V | 41.4~46.8V | 55.2~64.8V | |
保護(hù)模式:打嗝模式,異常條件移除后可自動恢復(fù) | ||||||
過溫度 | 打嗝模式,異常條件移除后可自動恢復(fù) | |||||
功能 | 風(fēng)扇開/關(guān)控制 | RTH3≧50°C風(fēng)扇開啟,≦40°C風(fēng)扇關(guān)斷 | ||||
環(huán)境 | 工作溫度 | -25~+70°C(請參考“減額曲線") | ||||
工作濕度 | 20~90% RH,無冷凝 | |||||
儲存溫度,濕度 | -40~+85°C,10~95% RH | |||||
溫度系數(shù) | ±0.03%°C(0~50°C) | |||||
耐振動 | 10~500Hz,5G 10分鐘/周期,X、Y、Z各60分鐘 | |||||
安規(guī) | 耐壓 | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-0.5KVAC | ||||
絕緣阻抗 | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25°C/70% RH | |||||
其它 | MTBF | ≥327.9K hrs. MIL-HDBK-217F(50°C) | ||||
尺寸 | 115*215 | |||||
包裝 | 紙盒包裝 | |||||
備注 | 主要用途 工業(yè)自動化控制,監(jiān)控安防設(shè)備,LED照明設(shè)備,科研設(shè)備,工控設(shè)備,電力設(shè)備,儀器儀表,液晶顯示器,電腦機(jī)箱電源,醫(yī)療設(shè)備等等 | |||||