污水處理設(shè)備 污泥處理設(shè)備 水處理過濾器 軟化水設(shè)備/除鹽設(shè)備 純凈水設(shè)備 消毒設(shè)備|加藥設(shè)備 供水/儲(chǔ)水/集水/排水/輔助 水處理膜 過濾器濾芯 水處理濾料 水處理劑 水處理填料 其它水處理設(shè)備
上海榮計(jì)達(dá)儀器科技有限公司
參 考 價(jià) | 面議 |
產(chǎn)品型號(hào)SZR-3
品 牌
廠商性質(zhì)其他
所 在 地
聯(lián)系方式:王林查看聯(lián)系方式
更新時(shí)間:2023-03-19 20:14:35瀏覽次數(shù):145次
聯(lián)系我時(shí),請(qǐng)告知來自 環(huán)保在線該儀器滿足GB4509-84《石油瀝青針入度的測(cè)量法》,ASMD5-83/IP49-79《瀝青針入度的測(cè)量法》和TO60-93《瀝青針入度試驗(yàn)》。該儀器使用簡(jiǎn)單、方便、低溫漂,帶有自動(dòng)控溫,LCD中文顯示,實(shí)時(shí)時(shí)鐘等功能
一、產(chǎn)品簡(jiǎn)介:
新型電腦瀝青針入度儀是一種采用數(shù)字式位移傳感器,結(jié)合微電腦技術(shù)研制的測(cè)量瀝青針入度測(cè)量?jī)x器,該儀器滿足GB4509-84《石油瀝青針入度的測(cè)量法》,ASMD5-83/IP49-79《瀝青針入度的測(cè)量法》和TO60-93《瀝青針入度試驗(yàn)》。該儀器使用簡(jiǎn)單、方便、低溫漂,帶有自動(dòng)控溫,LCD中文顯示,實(shí)時(shí)時(shí)鐘等功能,適用環(huán)境范圍大,實(shí)現(xiàn)了試驗(yàn)過程自動(dòng)化、數(shù)字化、電腦化、為我國公路、市政、建筑、石油等領(lǐng)域提供了一種精度高、穩(wěn)定度好、性能好的電腦自動(dòng)化瀝青試驗(yàn)儀器。
Product introduction:
The new computer asphalt penetration meter is a measuring instrument for measuring the penetration of asphalt that adopts a digital displacement sensor combined with microcomputer technology. The instrument meets GB4509-84 "Measurement of penetration of petroleum asphalt penetration", ASMD5-83 / IP49-79 "Asphalt penetration measurement method" and TO60-93 "Asphalt penetration test". The instrument is simple, convenient, low temperature drift, with automatic temperature control, LCD Chinese display, real-time clock and other functions, and has a wide range of applicable environments. It has automated, digitized, and computerized the test process. In other fields, a computer automated asphalt test instrument with high accuracy, good stability and good performance is provided.
二、技術(shù)參數(shù):
★*小分度:位移:0.01mm 時(shí)間:0.1s 溫度:0.1℃
★*大量程:40mm
★針連桿、砝碼、標(biāo)準(zhǔn)針合重:100±0.05g 150±0.05g
★控溫精度:0.1℃
★電源:AC220V±10%,50HZ
★試驗(yàn)皿:金屬制,平底狀,尺寸為70×45 55×35(mm)
★平底保溫皿:玻璃制品,容量大于1.5L,皿深大于60mm;附放試樣皿用三角架一個(gè)。
★外形尺寸:250X220X700mm
★重量:15kg
Technical parameters:
★ * Small graduation: Displacement: 0.01mm Time: 0.1s Temperature: 0.1 ℃
★ * Large range: 40mm
★ Needle connecting rod, weight, standard needle combined weight: 100 ± 0.05g 150 ± 0.05g
★ Temperature control accuracy: 0.1 ℃
★ Power supply: AC220V ± 10%, 50HZ
★ Testing dish: metal, flat bottom, size 70 × 45, 55 × 35 (mm)
★ Flat bottom insulation dish: glass products, the capacity is greater than 1.5L, the depth of the dish is greater than 60mm; a tripod is used for the sample dish.
★ Dimensions: 250X220X700mm
★ Weight: 15kg
三、使用方法:
★將預(yù)先脫水的試樣加熱溶化,加熱溫度不得高于試樣估計(jì)軟化點(diǎn)90℃,時(shí)間不得多于30min,充分?jǐn)嚢柽^篩后注入盛樣皿內(nèi)。其深度至少應(yīng)超過預(yù)期針入度值約10mm放置于15-39℃的室溫中冷卻1h,冷卻時(shí)應(yīng)注意不應(yīng)有灰塵落入。
★將盛樣 皿浸入盛滿清水的水槽中,保溫1-1.5h,水溫保持25±0.5℃,水面應(yīng)高于試驗(yàn)表面25mm以上。
★調(diào)整針入度儀,使之水平(必要時(shí)調(diào)節(jié)附加砝碼的重量)用手撳下釋放按鈕,提起標(biāo)準(zhǔn)針針桿,使針桿頂端面與百分表接觸頭接觸。
★盛樣皿保溫1-1.5h后取出并放入水溫嚴(yán)格控制為25℃的平底保溫皿中,試樣表面以上的水層高度應(yīng)不少于10mm,將保溫皿置于針入度儀的圓形工作臺(tái)上,調(diào)節(jié)工作臺(tái),使試樣表面與針尖恰好接觸(如調(diào)節(jié)工作臺(tái)不夠,可用調(diào)節(jié)螺母調(diào)節(jié)杠架與之配合),將百分表指針對(duì)零。
★將時(shí)間開關(guān)撥至試樣所需的時(shí)間(5s或60s)檔位上,按一下開始按鈕,電磁鐵吸合使標(biāo)準(zhǔn)針自由地穿入試樣中,至紅燈亮?xí)r(此時(shí),表示標(biāo)準(zhǔn)針穿入試樣中的時(shí)間已達(dá)5s或60s,電磁鐵自動(dòng)放磁彈簧將針桿固緊,使其針桿不再下落),用手按下百分表觸頭與標(biāo)準(zhǔn)針針外桿頂端面接觸,此時(shí)百分表指針?biāo)傅臄?shù),即為試樣的針入度。
★同一試樣重復(fù)試驗(yàn)至少三次,每次穿入點(diǎn)的相互距離及與盛樣皿邊緣的距離都不得小于10mm,各次試驗(yàn)結(jié)果的平均值即為此試樣的試驗(yàn)結(jié)果。
★每次試驗(yàn)前,都應(yīng)檢查并調(diào)節(jié)保溫皿內(nèi)的水溫,試驗(yàn)后都應(yīng)將標(biāo)準(zhǔn)針取下用浸有溶劑(汽油)的棉花或布拭凈,再用棉花或布擦干。
Third, use method:
★ The pre-dehydrated sample should be heated and melted, the heating temperature should not be higher than the sample's estimated softening point by 90 ° C, and the time should not be longer than 30 minutes. Its depth should at least exceed the expected penetration value by about 10mm. It should be cooled at room temperature of 15-39 ° C for 1 hour. During cooling, care should be taken to prevent dust from falling into it.
★ Immerse the sample container in a water tank filled with fresh water, keep it warm for 1-1.5 hours, keep the water temperature at 25 ± 0.5 ℃, and the water surface should be more than 25mm above the test surface.
★ Adjust the penetrometer to make it level (adjust the weight of additional weight if necessary). Press the release button with your hand to lift the standard needle bar so that the top surface of the needle bar contacts the dial contact head.
★ After the sample container is kept warm for 1-1.5 hours, the supplier Hebei Dahong Experimental Instrument Co., Ltd. takes it out and puts it in a flat-bottomed insulated dish whose water temperature is strictly controlled at 25 ° C. The height of the water layer above the surface of the sample should be not less than 10mm. Place the holding dish on the circular table of the penetrometer, adjust the table so that the surface of the sample just touches the tip of the needle (if the table is not adjusted, you can use the adjusting nut to adjust the lever bracket to match it). Pointer to zero.
★ Turn the time switch to the time (5s or 60s) position of the sample, press the start button, and the solenoid will pull the standard needle into the sample freely until the red light is on (at this time, Indicates that the standard needle has penetrated into the sample for 5s or 60s, and the electromagnet automatically releases the spring to tighten the needle bar so that the needle bar no longer drops), press the dial indicator contact and the standard needle The top surface of the outer rod is in contact. At this time, the number indicated by the pointer of the dial indicator is the penetration of the sample.
★ Repeat the test at least three times for the same sample, and the distance between each penetration point and the edge of the sample container shall not be less than 10mm. The average value of each test result is the test result of this sample.
★ Before each test, check and adjust the water temperature in the insulation dish. After the test, remove the standard needle and wipe it with cotton or cloth soaked with solvent (gasoline), then wipe it with cotton or cloth.
四、安裝與調(diào)試:
★新儀器開箱后,應(yīng)按裝箱單檢查配件是否齊全,有無損壞。將針入度儀主機(jī)放在水平的平臺(tái)上,接通電源,按住<手動(dòng)>鍵使電磁鐵吸合,將標(biāo)準(zhǔn)針的連桿插入傳感器的孔內(nèi),放開<手動(dòng)>鍵。把標(biāo)準(zhǔn)針與連桿聯(lián)接即可。
★開箱后,檢查是否因運(yùn)輸而發(fā)生故障。
★按裝箱清單檢查是否缺件,及時(shí)通知本公司銷售部或銷售商。
★將電源插上,打開電源,此時(shí)顯示屏顯示儀器名稱后進(jìn)入試驗(yàn)界面。
★為確保檢測(cè)精度,通電15S后,按下儀器的<手動(dòng)>鍵,此時(shí)針桿組件應(yīng)能自由落下。
★調(diào)整儀器水平方法如下:轉(zhuǎn)動(dòng)調(diào)節(jié)支角,使水平泡中氣泡處于中位置,此時(shí),工作平面已處于水平位置。
Fourth, installation and commissioning
★ After unpacking the new instrument, check whether the accessories are complete and damaged according to the packing list. Put the main body of the penetrometer on a horizontal platform, turn on the power, hold down the
★ After unpacking, check if there is any malfunction due to transportation.
★ Check for missing parts according to the packing list, and notify the sales department or the seller of the company in time.
★ Plug in the power and turn on the power. At this time, the display shows the instrument name and enters the test interface.
★ To ensure the detection accuracy, press the
★ The method of adjusting the level of the instrument is as follows: Turn and adjust the supporting angle so that the bubbles in the horizontal bubble are in the middle position. At this time, the working plane is already in the horizontal position.
您感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN
環(huán)保在線 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ?
請(qǐng)輸入賬號(hào)
請(qǐng)輸入密碼
請(qǐng)輸驗(yàn)證碼
請(qǐng)輸入你感興趣的產(chǎn)品
請(qǐng)簡(jiǎn)單描述您的需求
請(qǐng)選擇省份
聯(lián)系方式
上海榮計(jì)達(dá)儀器科技有限公司