產(chǎn)品特色
· Exceptional accuracy for insuring tight-control and minimizing costly out of specification conditions
· NEMA 4X rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists
· Robust sensor provides shock and vibration resistance insuring stability in controlling pressure for process applications
技術指標
Service Compatible gases and liquids
Wetted Materials Type 316, 316L SS
Accuracy 0.25% FS
Temperature Limit 0 to 176°F (-18 to 80°C)
Compensated Temperature Range 0 to 176°F (-18 to 80°C)
Thermal Effect ±0.02% FS/°F (includes zero and span)
Pressure Limits See Catalog page
Power Requirements 10 to 28 VDC
Output Signal 4 to 20 mA
Response Time 50 ms
Loop Resistance 0 - 900 Ω maximum
Current Consumption 38 mA (maximum)
Electrical Connections 3 ft. cable or 4-pin M-12 Connector
Process Connection 1/4" male/female NPT and BSPT
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Mount in any position
Weight 8.9 oz (252 g)
Agency Approvals CE, cULus Intrinsically Safe to UL Standard 913
For use in Hazardous (Classified) Locations:
Class I Div. 1 Groups A,B,C,D; Class II Div. 1 Groups E,F,G; Class III Div. 1.
Temperature Code: T4 @ 80°C ambient.
Install in accordance with control drawing 01-700797-00.
WARNING: To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. Use with approved safety barriers using entity evaluation.
選項配件
image | Model Number | Description |
A-295 | Female four pin M-12 to cable gland connector. | |
A-231 | 16' (5 m) shielded cable with 4 pin female M-12 connection. | |
A-251 | Pressure snubber, brass, 1/4" male/female BSPT. | |
A-257 | Pressure snubber, 316 SS, 1/4" male/female BSPT. | |
MTL7706 | Intrinsically safe zener barrier. |